Zeile 11: Zeile 11:
   * can handle up to 19 messages   * can handle up to 19 messages
   * 8 RICs with each 4 sub-RICs (A, B, C, D)   * 8 RICs with each 4 sub-RICs (A, B, C, D)
 +  * notification:​ tone and LED
   * IP67 rated (seems to be a product for healthcare: "​washable,​ anti-bacterial plastic case")   * IP67 rated (seems to be a product for healthcare: "​washable,​ anti-bacterial plastic case")
   * built-in 3.6V 600 mAh lithium battery (should last up to 5 days)   * built-in 3.6V 600 mAh lithium battery (should last up to 5 days)
Zeile 29: Zeile 30:
 Programming "on the fly" is possible for the most important parameters (RICs, frequency). Access to hand programming:​ Long press of green and red, default password 1234. (For more information on hand programming please see [[alphapocdescription|AlphaPoc 602R]]) ​ Programming "on the fly" is possible for the most important parameters (RICs, frequency). Access to hand programming:​ Long press of green and red, default password 1234. (For more information on hand programming please see [[alphapocdescription|AlphaPoc 602R]]) ​
  
-{{ :​alphapoc:​alphapoc:​606rics.jpg?400 |}}+{{ :​alphapoc:​alphapoc:​8008rubrics.jpg |}}
  
  
Zeile 43: Zeile 44:
 As the W8008 pager doesn'​t have a predefined RIC, the RIC will be assigned by the DAPNET support team, normally based on the existing CCS7 / DMR ID system. The POCSAG addresses are limited to 2^21 = 2097152, so IDs greater than the limit have to be shortened. It is not necessary to have a CCS7 / DMR ID to register a pager on DAPNET. As the W8008 pager doesn'​t have a predefined RIC, the RIC will be assigned by the DAPNET support team, normally based on the existing CCS7 / DMR ID system. The POCSAG addresses are limited to 2^21 = 2097152, so IDs greater than the limit have to be shortened. It is not necessary to have a CCS7 / DMR ID to register a pager on DAPNET.
  
-The reception of the rubrics originally designed for [[skyperdescription|Skyper]] described [[rubricactivationskyper|here]] is not as convinient ​on the W8008 as on the Skyper. But there is a workaround: The rubrics are transmitted in both Skyper format and as personal messages. The RIC used for the rubrics for this purpose is 1000 + <RUBRIC Number>. So e.g. rubric number 42 is RIC 1042. You can assign up to 8 POCSAG addresses (RICs), on your W8008 that it listen to. It is convinient ​to programm ​you personal RIC and besides ​the RIC of up to 7 rubrics. So you can still receive the rubics ​content on the W8008. A mayor drawback is, that the W8008 will not distinguish between ​thoses ​and really personal messages, filling up your display ​quite fast. +The reception of the rubrics originally designed for [[skyperdescription|Skyper]] described [[rubricactivationskyper|here]] is not as convenient ​on the W8008 as on the Skyper. But there is a workaround: The rubrics are transmitted in both Skyper format and as personal messages. The RIC used for the rubrics for this purpose is 1000 + <RUBRIC Number>. So e.g. rubric number 42 is RIC 1042. You can assign up to 8 POCSAG addresses (RICs), on your W8008 that it listen to. It is convenient ​to programm ​your personal RIC and additionally ​the RICs of up to 7 rubrics. So you can still receive the rubric ​content on the W8008. A major drawback is, that the W8008 will not distinguish between ​those and really personal messages, filling up your memory ​quite fast. 
  
-How to know the rubics ​and their numbers?+How to know the rubrics ​and their numbers?
 Log in to the DAPNET Web Interface on [[http://​hampager.de/#/​rubrics|http://​hampager.de/#/​rubrics]] and look them up. Be aware the not all numbers from 1 to 99 are present and that several rubrics are assigned to a local limited transmitter group. Log in to the DAPNET Web Interface on [[http://​hampager.de/#/​rubrics|http://​hampager.de/#/​rubrics]] and look them up. Be aware the not all numbers from 1 to 99 are present and that several rubrics are assigned to a local limited transmitter group.
  
Zeile 63: Zeile 64:
 Group messages have also another symbol on the pager display, see below: Group messages have also another symbol on the pager display, see below:
  
-{{ :​alphapoc:​alphapoc:​8008maildrop.jpg?​400|}}+{{ :​alphapoc:​alphapoc:​8008maildrop.jpg?​400 |}}
  
 You can use this opportunity to change the tone for the RIC to „disable“,​ if you prefer no sound on receiving rubric messages. You can use this opportunity to change the tone for the RIC to „disable“,​ if you prefer no sound on receiving rubric messages.
 +
 ===== out of range alert ===== ===== out of range alert =====
  
Zeile 79: Zeile 81:
  
 {{ :​alphapoc:​alphapoc:​8008outofrangesettings.jpg |}} {{ :​alphapoc:​alphapoc:​8008outofrangesettings.jpg |}}
 +
 +===== Over-The-Air Programming of Time and Date =====
 +
 +It seems as up to now the W8008 cannot get the date/time via OTA (over the air).
 +
 ===== Accessories ===== ===== Accessories =====
  
Zeile 84: Zeile 91:
   * Programming Station (connected via USB, also charging function)   * Programming Station (connected via USB, also charging function)
  
-The W8008 has no built-in usb interface, therefore you need the stations.+{{ :​alphapoc:​alphapoc:​8008stations.jpg?400 |}}
  
 +The W8008 has no built-in usb interface, therefore you need at least one of the stations.
 +The both stations look like the same, but the charging station has only 2 contacts, while the programming station has 8 contacts. ​
  
-{{ :​alphapoc:​alphapoc:​606station.jpg?400 |}}+Both stations have a micro usb connector on the side, which can be used for programming or for charging. It is also possible to connect a station to the USB connector of your laptop for charging. The delivered power supply of both stations has 1 ampere. While the pager stays on in the charging station, it switches off in the programming station while charging. 
 + 
 +{{ :​alphapoc:​alphapoc:​8008pagerinstation.jpg?400 |}} 
 + 
 +One issue when using the programming station for charging: While in the station, the time stops and will not be restored on removal.
  
 ===== Known bugs ===== ===== Known bugs =====
Zeile 99: Zeile 112:
 ===== Links ===== ===== Links =====
  
 +  * Telegramm-Gruppe (deutschsprachig):​ https://​t.me/​joinchat/​AF13KRBOP9aGIHOCuWq0eQ
   * http://​www.wex.com.hk/​products-detail.php?​pid=39   * http://​www.wex.com.hk/​products-detail.php?​pid=39
   * https://​www.alphapoc-europe.de/​Alphapoc-Meldeempfaenger-606R   * https://​www.alphapoc-europe.de/​Alphapoc-Meldeempfaenger-606R
   * German: Programmierung:​ http://​pager.dstar.at/​userfiles/​downloads/​Anleitung8008.pdf   * German: Programmierung:​ http://​pager.dstar.at/​userfiles/​downloads/​Anleitung8008.pdf
   * German: Anleitung Pager: http://​pager.dstar.at/​userfiles/​downloads/​HandhabungW8008.pdf   * German: Anleitung Pager: http://​pager.dstar.at/​userfiles/​downloads/​HandhabungW8008.pdf
- +  * Muster-Config (Achtung: OE-Frequenz 438,​025!): ​http://pager.dstar.at/Musterdatei438025.sav
-[[http://hampager.de/#/​rubrics|http://​hampager.de/#/​rubrics]]+
  
 Photos by DL1ITU, OE7BSH Photos by DL1ITU, OE7BSH